Use LRFD and choose a pipe to be used as a tension member to resist a service dead load of 10 kips and service live load of 25 kips. The end
Question
Use LRFD and choose a pipe to be used as a tension member to resist a service dead load of 10 kips and service live load of 25 kips. The ends will be connected by welding completely around the circumference of the pipe. The length is 8 feet.
in progress
0
Physics
5 years
2021-08-13T21:22:14+00:00
2021-08-13T21:22:14+00:00 1 Answers
35 views
0
Answers ( )
Answer:
see explanation
Explanation:
By load resistance and factor design:
calculate factored load using following load combination
D is dead load
L is live load
Substitute 10kips for D and 25kips for L
Calculate the required gross area 0f the member
substitute 52kips for
and 35kips for 
Calculate required effective area of the member
substitute 52kips for
and 60ksi for 
Calculate minimum value for radius of gyration
Corresponding to the above calculated value, try pipe 3 standard
For pipe 3 standard
Check the above section requirement
Calculate effective net area of the section
therefore the section is OK
Hence , use pipe 3 standard